OGINS 01.06 – Air Data Computer (ADC)

 

Results

Q1. A temperature sensor having a recovery factor of 0.75 indicates 30°C. Static Air Temperature (SAT) is 25°C. How high is the Ram-rise?

5°C

Q2. The standard temperature for all our aerodynamic computations is:

15°C or 59°F

Q3. The ram air temperature (RAT) is defined as:

SAT plus the ram rise.

Q4. In An Air Data Computer (ADC), aeroplane altitude is calculated from:

Measurement of absolute barometric pressure from a static source on the fuselage

Q5. To obtain total air temp. (TAT) the airflow to the sensor:

must be brought to rest without addition or removal of heat.

Q6. The recovery factor of a “flush bulb” temperature sensor generally varies from:

0.35 to 0.50

Q7. The advantages provided by an air data computer to indicate the altitude are: 1. Position/pressure error correction 2. Hysteresis error correction 3. Remote data transmission capability 4. Capability of operating as a conventional altimeter in the event of a failure. The combination of correct statements is:

1,3,4

Q8. An Air Data Computer (ADC):

Transforms air data measurements into electric impulses driving servo motors in instruments

Q9. The measurement of SAT (static air temperature) by direct means is not possible on some (fast) aircraft because:

of the effects from adiabatic compression and friction.

Q10. Given: Ts the static temperature (SAT), Tt the total temperature (TAT), Kr the recovery coefficient, M the Mach number. The total temperature can be expressed approximately by the formula:

Tt = Ts(1 + 0.2 M^2)